| Mobile cable electrolaboratory ETL-10 |
 |
|
| Mobile cable electrotechnical laboratory ETL-35 |
 |
|
| Complex mobile electrotechnical laboratory ETL-35K |
 |
|
|
 |
|
|
 |
|
|
| |
|
 |
|
| RIF-7 |
 |
|
| Diodiс Test Device АID-70/50 |
 |
|
| Automated setting for loss-angle tangent measurement of transformer oil TANGENT-3М |
 |
|
| UIM-90m Test Set for Accurate Measurement of the Breakdown Voltage of Insulating Fluids |
 |
|
| Bridge SA7100 |
 |
|
| High-Voltage Test Bench SVS-50 |
 |
|
| High-Voltage Test Bench SVS-100 |
 |
|
| Generator of Acoustic Blast Waves GAUV-5M |
 |
|
| High-Voltage Cable Test Bench for Finding Defective Insulation SVP |
 |
|
| Locating Complex K-40M |
 |
|
| Device for Testing Automatic Overload Controls UPA (UPA-10) |
 |
|
| Device for Testing Automatic Machines UPA-6 |
 |
|
| Multi-purpose Breakdown plant UPU-6 |
 |
|
| TVO Device for Measuring a Temperature of Oil Burst in an Open Crucible |
 |
|
| Testing Device AI-2500 (the analogue of РЕТОМ 2500) |
 |
|
| Test Transformer IOM-100/16 |
 |
|
|
 |
|
|
 |
|
|
Kharkovenergopribor Ltd.
Kharkiv, Ukraine
тел.: +380 (57) 393-10-69
тел.: +380 (57) 393-10-71
тел.: +380 (57) 755-17-71
e-mail:
|
|
SVS-50 : High-Voltage Test Bench SVS-50
|
|
Passport (in russian) SVS-50 : Download (134 Kb)
Manual (in russian) SVS-50 : Download (553 Kb)
|
Functions of test bench SVS-50
- High-voltage test bench SVS-50 is intended for testing insulating properties of protective equipment (insulating bars, rubber boats, gloves, an electrical tool, etc.) by variable high voltage of industrial frequency that is adjusted within the limits of 0 – 50kV.
- Test bench SVS-50 is intended for operation inside heated buildings.
The service conditions of test bench SVS-50 are:
| a range of air temperatures, оС | от 0 до +40
| | relative air moisture at a temperature of 25 оС | up to 80 %
| | atmospheric pressure, mm. hg | 650 and 800
|
Service of test bench SVS-50 is provided by one operator with the admission to working in circuits with voltage over 1000 V. The operator should have the third or a higher category of industrial safety to be permitted to work with electrical installations having voltage over 1000V.
Technical Data of Test Bench SVS-50
General parameters of test bench SVS-50
| Power supply is a single-phase network of an alternating current | with the voltage of 220 20 V, the frequency of 50 2 Hz
| | Power consumption up to, watt | 2000
| | Quantity of high variable voltage sources | 1
| | The area of the test bench (recommended), m2 | 2х2
| | Weight of the equipment up to, kg | 100
| | Test bench SVS-50 equipment life, years | 10
|
The Source Parameters
| Parameter | Type of a source is BHT-50 (AID-70/50)
| | The highest output voltage, kV | 50
| | The highest output current, mA | 50
| | Overall dimensions, mm | 350х315х625
| | Weight, kg | 35
|
The Test Bath Parameters
| Quantity of testing electrodes | 4
| | Overall dimensions, mm | 800х280х630
| | Weight at a dry condition, kg, no more than | 10
|
The Kilovoltmeter Parameters
| Measurement limits of voltage of an alternating current, kV | 0,1; 3; 15; 50
| | A reduced relative error of measurement, %, no more than | 3
|
The Alternating-Current Meter Parameters
| Measurement limits, mA | 1, 10
| | A reduced relative error of measurement, %, no more than | 4
|
|

|