| Mobile cable electrolaboratory ETL-10 |
 |
|
| Mobile cable electrotechnical laboratory ETL-35 |
 |
|
| Complex mobile electrotechnical laboratory ETL-35K |
 |
|
|
 |
|
|
 |
|
|
| |
|
 |
|
| RIF-7 |
 |
|
| Diodiс Test Device АID-70/50 |
 |
|
| Automated setting for loss-angle tangent measurement of transformer oil TANGENT-3М |
 |
|
| UIM-90m Test Set for Accurate Measurement of the Breakdown Voltage of Insulating Fluids |
 |
|
| Bridge SA7100 |
 |
|
| High-Voltage Test Bench SVS-50 |
 |
|
| High-Voltage Test Bench SVS-100 |
 |
|
| Generator of Acoustic Blast Waves GAUV-5M |
 |
|
| High-Voltage Cable Test Bench for Finding Defective Insulation SVP |
 |
|
| Locating Complex K-40M |
 |
|
| Device for Testing Automatic Overload Controls UPA (UPA-10) |
 |
|
| Device for Testing Automatic Machines UPA-6 |
 |
|
| Multi-purpose Breakdown plant UPU-6 |
 |
|
| TVO Device for Measuring a Temperature of Oil Burst in an Open Crucible |
 |
|
| Testing Device AI-2500 (the analogue of РЕТОМ 2500) |
 |
|
| Test Transformer IOM-100/16 |
 |
|
|
 |
|
|
 |
|
|
Kharkovenergopribor Ltd.
Kharkiv, Ukraine
тел.: +380 (57) 393-10-69
тел.: +380 (57) 393-10-71
тел.: +380 (57) 755-17-71
e-mail:
|
|
SVP : High-Voltage Cable Test Bench for Finding Defective Insulation SVP
Functions of SVP
High-Voltage Test Bench for Finding Defective Insulation of Cables SVP is intended for burning defective insulation of cables with its subsequent afterburning.
Service Conditions of SVP: :
| a range of air temperatures, оС | -20 -… +40
| | relative air moisture at a temperature of 25 оС | up to 80 %
| | atmospheric pressure, mm. hg | 650 and 800
|
Power supply of SVP is from an industrial single-phase network of 220V, 50Hz. Power supply from the independent power supply generator with capacity power not less than 4,0 kV-A is available. For full capability of SVP the capacity of a generator should be not less than 25 kVA.
Technical Data of SVP
General Technical Data of SVP
| Power supply is a single-phase network of an alternating current | with the voltage of 220+/-20V, the frequency of 50+/-2 Hz
| | Power consumption up to, watt | 100
| | Parameters of a kilometer measuring high direct voltage: measurement limits at direct voltage, kV
| 30
| | Weight of the equipment up to, kg | 100
| | Service staff | not fewer than 2 operators
| | Test bench SVP equipment life, years | 10
|
Insulation Test Block BPR-25/8
| A maximal output voltage at an idling mode, kV | 25
| | A minimal output voltage at an idling mode, kV | 1
| | A quantity of insulation testing stages | 5
| | The maximal current of the insulation test unit at a short circuit mode, A, not fewer than | 16
| | Maximal voltage of insulation afterburning at an idling mode, V | 500
| | A maximal current of insulation afterburning at an idling mode, A, not fewer than | 32
| | Power consumption of the insulation test unit, kVA, up to | 18
| | Power giving as a load, kVA, not fewer than | 8,5
| | An operating mode of the insulation test unit | long
| | Overall dimensions, mm | 495х350х560
| | Weight, kg, up to | 90
|
Equipment of SVP
| № | Name | Quantity |
| 1 | Control unit of test bench SVP | 1
| | 2 | Insulation test unit BPR-25/8 | 1
| | 3 | A set of cables | 1
| | 4 | A network throttle | 1
| | 5 | A high-voltage throttle | 1
| | 6 | High-Voltage Test Bench for Finding Defective Insulation of Cables SVP. A certificate. SVP/05.00.00.00PS | 1
| | 7 | High-Voltage Test Bench for Finding Defective Insulation of Cables SVP. A manual. SVP/05.00.00.00RE | 1
|
|
|
Go to top
|
|